Welcome to Shanghai Huyuan Refrigeration Engineering Co., Ltd.
Platinum series

Product Introduction

One: the status of indoor environmental pollution

1: Facing the home environment problem 

2: The harm of the indoor environment invisibly affects our health
1): Not pay attention to formaldehyde damage ;
2): Not pay attention to pm2.5 harm 
3): Not pay attention to the oxygen-deficient environment
4): Not pay attention to carbon dioxide hazard 
5): Not pay attention to the harm of germs



Two:The disadvantage of traditional oxygen production method
1: Window ventilation is easy to cause outdoor polluted air to be introduced into the room;
2: Adding a new air purification unit will affect the air conditioning load loss, that is, the investment in the air conditioning system will increase;
3: Energy consumption increases;
4: Green plants are slower in oxygenation and cannot be effectively increased in a short period of time.


Three: carbon dioxide troubles
1: Traditional carbon dioxide treatment: Add a fresh air system and chemical treatment.
2: Traditional treatment of carbon dioxide deficiency: energy waste; increased house price humidity; high maintenance costs; chemical treatment at home is not suitable.


Four: the trouble of formaldehyde
1: Traditional method of treating formaldehyde: adding fresh air purification system; photocatalyst; negative ion generator; activated carbon.
2: Insufficient traditional treatment of formaldehyde: causing a large amount of waste in waste; increasing room humidity, especially in the yellow mold season; authoritative reports show that photocatalyst can not effectively treat formaldehyde; negative ions become furnishings, can not solve large-area formaldehyde pollution; activated carbon is saturated in a short time, about 20 days.


Five: How to remove formaldehyde, if we can’t remove it how to deal with it ?
Traditional formaldehyde treatment methods: physical adsorption, chemical decomposition, biological metabolism and so on.
Physical adsorption: activated carbon;
Chemical decomposition: nanocatalysis, photocatalyst (eliminated in Western countries);
Biological metabolism: various kinds of plants.


Six: Oxygenerator fresh air purification Three-in-one Machine 

Three in one: oxygenerator, fresh air, purification
House: formaldehyde, pm2.5, tvoc, co2, harmful bacteria, harmful particles, etc.
Get: forest oxygen bar, aldehyde-free, flawless, sterile clean sweet air, suitable carbon dioxide concentration.


Seven: Comparison of Oxygenerator fresh air purification Three-in-one Machine and fresh air full heat purification

Comparison between oxygen-making fresh air purification trinity machine 

and fresh air full heat purification

Types of

 Oxygenerator fresh air purification Three-in-one Machine

Fresh air purification products

Features

The molecular sieve technology is used to pass the outdoor air through the purification process and extract the medical grade oxygen into the room. At the same time, the indoor dirty air and nitrogen and carbon dioxide are excluded from the outdoor; while the indoor positive pressure state is maintained, the outdoor polluted air is not easy to enter the room.

Through the introduction of outdoor polluted air, it is sent to the room through the treatment, and discharged to the outside through the exhaust fan; the ceiling pipe is required to cooperate, and the decoration is coordinated before; it is easy to cause secondary pollution problems.

performance

Free oxygen, internal circulation, external circulation mode; oxygen concentration in the supplemental room (21%) is necessary to maintain life metabolism; supplemental indoor oxygen is clean oxygen, does not produce the burden of filter materials, using medium-efficiency filter treatment indoor Pollute the air and maintain a reasonable concentration of carbon dioxide to maintain an ecological environment.

Commonly used equipment is connected to fresh air import and export and indoor import and export. The fresh air introduced into the outdoor air is sent to the room through air filtration and activated carbon treatment. The indoor air is discharged to the outside through the exhaust fan, and the fresh air and exhaust air are recovered through the heat exchange device. It is easy to cause the filter and activated carbon to reach saturation concentration for a short time; the heat recovery efficiency is low, generally below 30%, which is ineffective.

Moisturizing

Solving the problem of humidity in Huangmeitian, because it is extracted into the room through the oxygen in the air, instead of directly sending the outdoor high-humidity air into the room, it is easy to control the humidity in the room and maintain the comfortable humidity range of the human body.

The outdoor fresh air passes through the filtering process and is directly sent into the room, increasing the humidity concentration of the room. It is necessary to turn on the air conditioning and cooling mode. During the dehumidification process, a large amount of electricity is consumed, and the cold air affects the human body's discomfort and easily causes air conditioning diseases;

Energy saving

In the process of replenishing indoor oxygen, there is no loss of room cooling, and energy saving is 30-60%.

The indoor cooling capacity is discharged to the outside, the air conditioning burden is increased, and the air conditioning cost and operating cost are increased.

Oxygen

The oxygen concentration is freely adjusted, the medical grade humidity is soft and oxygen, and the concentration of 30-92% is freely adjusted, and the indoor air oxygen concentration is maintained within a reasonable range of 20-22% of human life metabolism.

The indoor oxygen concentration cannot be adjusted freely. After the design and installation, the changes in the personnel environment cannot be freely adjusted, resulting in a large amount of waste, and the control of oxygen supply cannot be achieved.

Safety

Most functional sites are severely deprived of oxygen, causing a series of diseases, supplementing indoor oxygen to maintain normal life oxygen concentration; setting switch during internal setting, optional oxygen concentration control sensing system, multi-functional adjustment adjustment; Slowly increase for a long time, no safety hazards arise.

The indoor floor height is generally 2.7-2.8 meters, a large number of pipes, in order to improve the top of the sling, the pipe wearing beam is easy to cause safety hazards; the filter, heat exchanger pollution situation is easy to cause secondary hazards; outdoor multi-component pollution air harmful components, in Individual harmful components can only be easily reduced during processing.

control

Intelligent touch screen control, optional app, smart home, wireless control, carbon dioxide, tvoc, formaldehyde, oxygen concentration, pm2.5 sensor control free options, to achieve indoor free adjustment control.

The control is single, the market generally has three-speed control, and the added control sensor has no practical realization value; the control device has high cost and is difficult to install.

use

User-friendly touch control, freely adjusted according to indoor environment changes, can be customized personalized, color matching, easy to use.

It can't be adjusted freely, it can be adjusted freely, mechanical adjustment function, single function.

installation

Vertical, wall-mounted, as long as the opening diameter is 110mm; easy to install, one person can operate, labor costs are low, installation time is 1-2 hours; installation personnel training period is short, generally 1-2 hours, installation The cost is 200-300 yuan; the combination of standardized pipe fittings, the installation conditions are safe and reliable, and the risk may be reduced; it can be installed after renovation.

The external wall needs to open a hole of 110-160mm. The indoor two-way pipe system is complicated to install. It needs to be closely coordinated with relevant professional. The installation is in place before the decoration; the installation period is longer 7-10 days; the installation material labor cost is higher 1800-5500 yuan. ; affect the overall decoration effect.

Cost

Lower cost

Higher installation costs and higher total cost

maintain

Low maintenance cost, filter replacement 1-2 times / two years, one maintenance cost 200-250 yuan, simple replacement, user replacement; molecular sieve life 5-6 years, replacement cost 600-800 yuan.Easy to repair, no need to remove the ceiling.

The maintenance cost is high, the filter is replaced 4-8 times/two years, and the maintenance cost is 400-650 yuan. The replacement is complicated, the user can not replace it by himself, the professional is required, and even the ceiling is removed; the ceiling needs to be removed for maintenance and repair.

life

8-10 years

5-8 years

Function: Through the introduction of outdoor polluted air, it is sent to the room through the treatment, and discharged to the outside through the exhaust fan; it needs to cooperate with the ceiling pipe to cooperate with the decoration; it is easy to cause secondary pollution.
Performance: Common equipment is connected to fresh air import and export and indoor import and export. Fresh air introduced into the outdoor air is sent to the room through air filtration and activated carbon treatment. The indoor air is discharged to the outside through the exhaust fan, and the fresh air and exhaust air are recovered through the heat exchange device. The amount of pollution easily causes the filter and activated carbon to reach a saturated concentration for a short time; the heat recovery efficiency is low, generally below 30%, which is ineffective.
Moisturizing: The outdoor fresh air passes through the filtering process and is directly sent into the room, increasing the humidity concentration of the room. It is necessary to turn on the air conditioning and cooling mode. During the dehumidification process, a large amount of electricity is consumed, and the cold air affects the human body's discomfort and easily causes air conditioning diseases.
Energy saving: indoor cooling capacity is discharged to the outside, air conditioning burden is increased, and air conditioning cost and operating cost are increased.
Oxygen-protection: The oxygen concentration in the room cannot be adjusted freely. After the design and installation, the change of the personnel environment cannot be freely adjusted, resulting in a large amount of waste and the control of oxygen supply.
Safety: The indoor height is generally 2.7-2.8 meters, a large number of pipelines, in order to improve the top of the sling, the pipeline is easy to cause safety hazards; the pollution of the filter and heat exchanger is easy to cause secondary damage; the outdoor multi-component pollution air harmful components In the process of treatment, you can only reduce individual harmful components.
Control: Single control, the market generally has three-speed control, and the added control sensor has no practical realization value; the control device has high cost and is difficult to install.
Use: Open and open, unable to adjust freely, mechanical adjustment function, single realization function.
Installation: the external wall needs to open a hole 110-160mm, the indoor two-way pipeline system, the installation is complex, need to closely cooperate with the relevant professional, the installation is in place before the decoration; the installation period is longer 7-10 days;
Cost: The labor cost of the installation materials is higher than 1800-5500 yuan; affecting the overall decoration effect.
Higher installation costs and higher total cost
Maintenance: The maintenance cost is high, the filter is replaced 4-8 times/two years, and the maintenance cost is 400-650 yuan. The replacement is complicated, the user can't replace it by himself, need professional staff, and even need to remove the ceiling; maintenance and repair need to remove the ceiling.
Life expectancy: 5-8 years


Eight: three modes

Free oxygen mode:

 Provide medical grade 45-95% oxygen concentration; built-in humidification bottle freely adjust oxygen; plug and play, use one press to go down, convenient for the elderly; freely adjust and adjust oxygen concentration; convenient for emergency patients, no need for help Use a sub-healthy population to supplement oxygen;

Inner loop mode:

Remove the humidified bottle, the medical grade 45-95% oxygen freely diffused room;

Indoor pm2.5 micro-particles pass micro-electrostatic dust removal, h13 high-efficiency filtration and filtration, adsorption of formaldehyde, clean air provided; through nano-light-collecting device, decomposition of formaldehyde, tvoc, and efficient sterilization; because outdoor air is separated by oxygen, it is beneficial to solve Huangmei weather humidity problem.

External circulation mode:

In the winter and summer season, it is only necessary to turn on the external circulation mode. The outdoor air is filtered, decomposed and absorbed by the tank to provide clean and sterile air. It is energy-saving and reliable; it can open the external circulation in a large concentration of carbon dioxide and formaldehyde to facilitate rapid reduction of indoor harmful gas concentration. 


Nine: Advantage of Oxygenerator fresh air purification Three-in-one Machine 


Ten: Intelligent Control:


User-friendly touch screen, display switch, oxygen absorption, purification, internal and external circulation change, timing function, realize free oxygen absorption, internal circulation, external circulation, air purification, solve Huangmeitian humidity trouble, convenient and easy to use operation; optional smart app Customized, smart home interface; provide customized free display of oxygen, pm2.5, carbon dioxide concentration, formaldehyde, tvoc and other parameters.




Eleven: product series parameters

Platinum series


Equipment power supply: voltage 220v 50nz
Power: 245w of oxygen system, 60w of fresh air purification system, and 20w of exhaust system power.(including electronic control total power 330w)
Oxygen system parameters: oxygen concentration 95% - 45%, oxygen flow 2L / min - 8L / min.
Purification system: Purifying air volume 130-180m3/h Exhaust air volume 50-80m3/h.
Purification efficiency: harmful particle pm2.5 removal rate 98%, formaldehyde removal rate: 98%, microbial removal rate: 98%, noise ≤ 45db (A),
Use area: 40-80m2. 
Volume: height 680mm width 460mm thickness 300mm
intelligent control



Twelve .Case Case picture